New electronic:
Thanks to its innovative electronic circuitry, the controller consumes only 0.2 watts in standby mode, a significant reduction when compared to other commercially available controllers which draw between 6 and 15 watts from the grid. This saves up to 128 kWh per year and reduces CO2 emissions by up to 97% or 70 kg per year.
Programmable functions:
- Adjustable run-on time: unnecessary pump operation can be limited. This helps to reduce power consumption.
- Overfrequent starting detection: more than 25 pump starts per hour are unusual. Often they are a sign of a continually flushing toilet or a dripping garden watering tap and could harm the pump. Therefore, ZETA 02 pump controller can shut down the pump in this case.
- Continuous pump operation: A great deal of water can be lost if a pipe ruptures or a gar- den hose bursts. For this reason, you can program the pump controller to detect continuous pump operation lasting more than ten minutes and to shut down the pump.